维普中文期刊产品整合服务

Hydrodynamics of a Newly China-Made Jiuling Bileaflet Heart Valve Prostheses

查看全文 作  者:CHU Yin ping 1,CHEN Ru kun 2,FAN Yu bo 3 , PU Fang 31 Department of Thoracic & Cardiovascular Surgery Second Hospital Affiliated Shanxi Medical University, Taiyuan 030001,China 2 Second Affiliated Hospital of Zhejiang University Medical 高影响力作者 出  处:《Chinese Journal of Biomedical Engineering(English Edition)》索引2000年第9卷第4期,共12页高影响力期刊 摘  要:Jiuling bileaflet prosthetic heart valve is manufactured in compliance with the national standard of P.R.C. GB12279 90. This mechanical heart valve substitute is constructed entirely of solid low temperature pyrolytic carbon. There is no graphite substrate within the leaflets or orifice. This prosthesis presents with satisfactory histocompatibility and induces little hemocoagulation around it. Objective: This study aimed to assess the hydrodynamic function of the newly China made Jiuling bileaflet heart valve prostheses. Methods: Jiuling valve has been tested in a pulsatile flow simulator in the aortic position. The testing condition was set at the pulsatile frequency of 55, 75, and 100 beats/min and a constant cardiac output of 4 L/min. The mean pressure differences, leakage volumes and closing volumes across each valve, and the effective orifice areas have been analyzed. Results: The Jiuling heart valves prosthesis had the lowest pressure difference at any given tissue annulus diameter. The mean pressure difference of all the Jiuling valves decreases with increasing the tissue annulus diameter or pulse frequency, and is in the range of below 10 mmHg. CarboMedics (CarboMedics, Inc., Austin, Tex.) is similar to that of the 21 mm and 23 mm Jiuling heart valves at the given pulse rate under 4 L/min. C L tilting disc valve (Lanzhou CarboMedics Inc., China) is similar to that of the 23 mm Jiuling heart valve. The effective orifice area of the Jiuling mechanical valve increases with increasing the tissue annulus diameter or pulse frequency. CarboMedics and C L tilting disc valve is similar to that of the 21 mm and 23 mm Jiuling heart valves. The Closing volume of the Jiuling prosthetic cardiac valves increases with increasing the tissue annulus diameter, but decreases with increasing the pulse frequency, and is in the range of below 11% (normalized by stroke volume). CarboMedics is below 16.5% of stroke volume; and C L tilting disc valve is below 7.5%. The leakage volume of the Jiuling prosthetic cardiac valves increases with increasing the tissue annulus diameter, but decreases with increasing the pulse frequency, and are in the range of below 28.9% (normalized by stroke volume). The leakage volume of CarboMedics is higher than that of the same sized 25 mm Jiuling valve, and the C L tilting disc valve is also higher than that of Jiuling valve at 4 L/min. Conclusion: For a given tissue diameter, the Jiuling valve showed significantly better hemodynamic characteristics. The material used in the construction is biocompatible, durable, and thromboresistant. The design permits light weight, low profile, and high ratio of flow area to tissue annulus diameter. 关 键 词:In vitro PULSATILE duplicator HEART VALVE SUBSTITUTE Jiuling HEART VALVE PROSTHESIS
相关文献

引证文献(8)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费