维普中文期刊产品整合服务

Self-heating Probe Instrument and Method for Measuring High Temperature Melting Volume Change Rate of Material

查看全文 作  者:WANG [1]Junwei;WANG [1,2,3]Zhiping;LU [1,2]Yang;CHENG [1]Bo 高影响力作者 机构地区:[1]College of Materials Science and Engineering, Lanzhou University of Technology;[2]State Key Laboratory of Gansu Advanced Non-ferrous Metal Materials, Lanzhou University of Technology;[3]Renewable Energy Laboratory, Lanzhou University of Technology高影响力机构 出  处:《Chinese Journal of Mechanical Engineering》索引2013年第26卷第2期,共6页高影响力期刊 基  金:supported by Gansu Provincial Critical Patented Projects of China(Grant No. 1101ZSB117);Gansu Provincial Science and Technology Pillar Program of China(Grant No. 1002ZSB018) 摘  要:The castings defects are affected by the melting volume change rate of material. The change rate has an important effect on running safety of the high temperature thermal storage chamber, too. But the characteristics of existing measuring installations are complex structure, troublesome operation and low precision. In order to measure the melting volume change rate of material accurately and conveniently, a self-designed measuring instrument, self-heating probe instrument, and measuring method are described. Temperature in heating cavity is controlled by PID temperature controller; melting volume change rate υ and molten density are calculated based on the melt volume which is measured by the instrument. Positive and negative υ represent expansion and shrinkage of the sample volume after melting, respectively. Taking eutectic LiF+CaF2 for example, its melting volume change rate and melting density at 1 123 K are -20.6% and 2 651 kg/m-3 measured by this instrument, which is only 0.71% smaller than literature value. Density and melting volume change rate of industry pure aluminum at 973 K and analysis pure NaCl at 1 123 K are detected by the instrument too. The measure results are agreed with report values. Measuring error sources are analyzed and several improving measures are proposed. In theory, the measuring errors of the change rate and molten density which are measured by the self-designed instrument is nearly 1/20-1/50 of that measured by the refitted mandril thermal expansion instrument. The self-designed instrument and method have the advantages of simple structure, being easy to operate, extensive applicability for material, relatively high accuracy, and most importantly, temperature and sample vapor pressure have little effect on the measurement accuracy. The presented instrument and method solve the problems of complicated structure and procedures, and large measuring errors for the samples with high vapor pressure by existing installations. 关 键 词:体积变化率 测量装置 测量仪器 高温熔融 材料 热探针 温度控制器 密度计算
相关文献

参考文献(17)

引证文献(2)

耦合文献(31)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费