维普中文期刊产品整合服务

Comparison of flow rate accuracy and consistency between the on-Q, baxter, and ambu pain infusion devices

查看全文 作  者:Michelle Le [1]Riger;Tarun [1]Bhalla;David [1]Martin;Jacob [1]Bettesworth;Joseph D [1,2]Tobias 高影响力作者 机构地区:[1]Departments of Anesthesiology and Pain Medicine, Nationwide Children’s Hospital and the Ohio State University, Columbus, OH 43205, United States;[2]Departments of Pediatrics, Nationwide Children’s Hospital and the Ohio State University, Columbus, OH 43205, United States高影响力机构 出  处:《World Journal of Anesthesiology》索引2014年第3卷第1期,共5页高影响力期刊 摘  要:AIM: Providing analgesia via peripheral nerve catheters attached to an infusion pump is an effective pain management option in children.METHODS: Portable infusion pumps are being used with increased frequency in pediatric patients. Because these pumps are infusing potentially toxic doses of medications, the accuracy and consistency of these devices becomes very important in this patient population. This study is a comparison of the actual delivery volume of local anesthetic of three elastomeric infusion devices approved for patient use in the ambulatory setting. Three brands of disposable elastomeric infusion devices were used(Five On-Q, Five Baxter, and Five Ambu pumps). Each was filled with 200 m L of Ropivicaine 0.1% and connected to a single, end hole infusion catheter and set to infuse at 12 m L/h. The devices were run simultaneously. The fluid delivered was measured every hour with a graduated column over a tenhour period. The ambient temperature was also recorded.RESULTS: There were statistically significant differences in the output from each elastomeric device over the 10 h infusion period when compared to the nominal rate of 12 m L/h. The output from the Ambu and Baxter pumps was less than that set on the regulator, while the output from the On-Q pump was greater than that set on the regulator. The results remained statistically significant after adjusting the nominal rate to correct for differences in temperature. The Ambu infusion device was the most consistent, while the Baxter infusion device was the most accurate. This emphasizes the importance of health care providers understanding the infusion profile of the pump being used for continuous peripheral nerve block, as these alterations in flow could result in inadequate analgesia, early reservoir exhaustion, excessive muscle weakness or potential toxicity, especially when used in pediatric patients.CONCLUSION: This investigation demonstrates that three modern elastomeric infusion pumps have significantly different output than the nominal rate set on the regulator. 关 键 词:PEDIATRIC ANESTHESIA PAIN Regional ANESTHESIA PAIN PUMPS Acute PAIN
相关文献

参考文献(11)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费