Analysis of delivery and recalculation of dose using DICOM treatment records

查看全文 作  者:[1]Z.Chen;[1]M.F.Moyers;[1]Y.Deng;[1]H.L.Chen;[1]J.Li;[1]Z.M.Shen;[1]J.Lin;[2]Q.Wang;[2]P.Yepes 高影响力作者 机构地区:[1]Shanghai Proton and Heavy Ion Center,Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy,Shanghai Key Laboratory of Radiation Oncology,Shanghai 201315,China;[2]Rice University,Houston,TX,United States高影响力机构 出  处:《Radiation Medicine and Protection》索引2022年第3卷第3期,共8页高影响力期刊 摘  要:Objective:A procedure has been proposed for patient-specific QA that,instead of comparing a measurement to the planned dose,compares the dose calculated by an independent system to the dose calculated by the planning system.It is still prudent,however,to check the accuracy of the beam delivery.For this purpose,the DICOM records from the first treatment fraction can be compared to the planned treatment using an in-house developed planning system.Methods:Totally 1,398 patient portals were subjected to the new QA procedure.The dose distribution for each portal was first recalculated on a water phantom by two treatment planning systems and the dose distributions were compared.When agreement was observed,the patient was allowed to start treatment without a measure-ment.The record from the first day was imported into an in-house planning system which was used to evaluate the delivery for errors and calculate the delivered dose distribution and compare it to the planned dose distribution.Results:A total of 266 portals passed a strict comparison between the clinical and QA dose calculations and directly used for treatment without measurements.For those portals,the comparison of the delivery records to the plan showed that 99%of spot positions deviated less than 0.2 mm and 99.7%of spot metersets deviated by less than 0.3%.On the other hand,64 portals showed spot size deviations greater than the tolerance of15%with some as large as25%.For 32 portals in which the record was used to calculate the delivered dose distribution,the Gamma passing rates between the planned and delivered distributions were always above 95%using a 2%dose difference and 2 mm distance-to-agreement criteria.Conclusions:The new QA process has been implemented slowly with strict constraints.The amount of beam time required has been reduced while maintaining safety. 关 键 词:Ion beam Quality assurance Monte Carlo DICOM
相关文献

参考文献(22)

引证文献(2)

耦合文献(1)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费