维普中文期刊产品整合服务

Large area^(3)He tube array detector with modular design for multi‑physics instrument at CSNS

查看全文 作  者:Lin [1,2,3]Zhu;Jian‑Rong [1,2,3]Zhou;Yuan‑Guang [1,2]Xia;Liang [1,2]Xiao;Hong [1,2]Luo;Xiao‑Juan [1,2]Zhou;Wen‑Qin [1,2,3]Yang;Bei‑Ju [1,2]Guan;Xing‑Fen [1,2]Jiang;Yan‑Feng [1,2]Wang;Hong [2]Xu;Hai‑Yun [2]Teng;Li‑Xin [2]Zeng;Jia‑Jie [2]Li;Lei [2]Hu;Ke [2]Zhou;Yong‑Xiang [2]Qiu;Pei‑Xun [2]Shen;Jun [2]Xu;Li‑Jiang [2]Liao;Xiao‑Zhuang [2]Wang;Gui‑An [1,2]Yang;Huai‑Chan [2]Chen;Ju‑Ping [2]Xu;Zhi‑Duo [2]Li;Song‑Lin [2]Wang;Jian [2]Zhuang;Yu‑Bin [1,2,3]Zhao;Jun‑Rong [2]Zhang;Wen [2]Yin;Zhi‑Jia [1,2,3]Sun;Yuan‑Bo [1,2]Chen 高影响力作者 机构地区:[1]Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049,China;[2]Spallation Neutron Source Science Center,Dongguan 523803,China;[3]University of Chinese Academy of Sciences,Beijing 100049,China高影响力机构 出  处:《Nuclear Science and Techniques》索引2023年第34卷第1期,共12页高影响力期刊 基  金:supported by the National Key R&D Program of China (No. 2021YFA1600703);National Natural Science Foundation of China (No. 12175254);Youth Innovation Promotion Association CAS 摘  要:The multi-physics instrument(MPI)is the first user cooperative instrument at the China Spallation Neutron Source(CSNS).It was designed to explore the structures of complex materials at multiple scales based on the neutron total scattering technique.This imposes the requirements for the detector,including a high detection efficiency to reduce the measurement time and a large solid angle coverage to cover a wide range of momentum transfers.To satisfy these demands,a large-area array of 3He-filled linear position-sensitive detectors(LPSDs)was constructed,each with a diameter of 1 inch and pressure of 20 atm.It uses an orbicular layout of the detector and an eight-pack module design for the arrangement of 3He LPSDs,covering a range of scattering angles from 3°to 170°with a total detector area of approximately 7 m2.The detector works in air,which is separated from the vacuum environment to facilitate installation and maintenance.The characteristics of the MPI detector were investigated through Monte Carlo(MC)simulations using Geant4 and experimental measurements.The results suggest that the detectors are highly efficient in the wavelength range of the MPI,and an efficiency over 25%is achievable for above 0.1 A neutrons.A minimal position resolution of 6.4 mm full width at half maximum(FWHM)along the tube length was achieved at a working voltage of 2200 V,and a deviation below 2 mm between the real and measured positions was attained in the beam experiment.The detector module exhibited good consistency and an excellent counting rate capacity of up to 80 kHz,which satisfied the requirements of experiments with a high event rate.Observations of its operation over the past year have shown that the detector works steadily in sample experiments,which allows the MPI to serve the user program successfully. 关 键 词:Neutron detector LPSD Position resolution Counting rate capacity
相关文献

参考文献(25)

引证文献(1)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费